Updated: · DomPrzegląd editorial team
List of inspections
| Inspection | How often | Legal basis |
|---|---|---|
| Chimney and ventilation ducts | at least once a year | Art. 62(1)(1)(c) |
| Gas installation | at least once a year | Art. 62(1)(1)(c) |
| Technical condition, electrics, lightning protection | at least every 5 years | Art. 62(1)(2) |
| Duct cleaning (solid fuel) | every 3 months | 2010 fire protection regulation |
| Duct cleaning (gas, oil) | every 6 months | 2010 fire protection regulation |
What a house owner does not have to do
A single-family house is exempt from the yearly check of weather-exposed elements (Art. 62(2)). A building logbook is not required either. Still, keep the reports: without them it is hard to prove that checks took place.
Consequences of missing inspections
Failing to carry out a mandatory check is a petty offence under Art. 93 of the Construction Law and may be fined. A missing chimney report can also make it harder to get compensation after a fire — many insurance policies require installations in working order.
How not to miss a date
Enter the dates of your last inspections in the calendar. You will see what is overdue, and the House logbook will email you before the next dates.
Who may carry out the inspection
- Chimney ducts: a master chimney sweep or a person with building qualifications in the installations specialty.
- Gas installation: a person with building qualifications in the installations specialty or qualifications to supervise gas appliances.
- Five-year inspection: a person with building qualifications in the relevant specialty; electrical testing — an electrician qualified for measurements.
How long it takes
A chimney inspection in a single-family house usually takes under an hour, a gas check about the same. A five-year inspection with electrical testing usually means a few hours on site plus writing the report.
Frequently asked questions
Does a new house need inspections too? Yes, the periods start when the building is put into use.
Can I combine inspections? Yes. In the year of the five-year check it can be combined with the yearly chimney and gas checks if the inspector holds the right qualifications.
A sample year for a single-family house
| Month | What to do |
|---|---|
| September | chimney inspection and flue cleaning before the heating season |
| October | gas installation check and boiler service |
| December, March | further cleaning of smoke flues for a solid-fuel boiler (every 3 months in season) |
| April | look over the roof, gutters and flashings after winter |
| every 5 years | five-year inspection with measurements of the electrical installation and lightning protection |
Ventilation ducts count too
The chimney inspection covers not only smoke and flue-gas ducts, but ventilation ducts as well. Under the Polish fire protection regulation, ventilation ducts must be cleaned at least once a year, unless the conditions of use require more frequent cleaning. Blocked ventilation in a bathroom or kitchen is one of the main causes of damp walls and mould.
A house with a heat pump or photovoltaics
If the house has no smoke chimney and no gas, the mandatory chimney inspection is limited to the ventilation ducts. A photovoltaic system and a heat pump are part of the building's electrical installation, so their condition and protection devices are assessed in the five-year inspection. Manufacturers usually also require their own service inspections, on which the warranty depends.
What to prepare before the visit
- the previous report from the same type of inspection,
- documents of the boiler or stove (type, class, installation date),
- free access to soot doors, the attic and the roof,
- a list of defects you noticed during the year.
When the inspector finds a defect
If there is an immediate hazard, for example no draught in the flue of a gas boiler, the inspector may recommend switching the appliance off at once. Other recommendations have a deadline in the report. After the repair, ask for a short note confirming that the defect has been fixed — it helps at the next inspection and in dealings with your insurer.
Sources
- Ustawa Prawo budowlane (Dz.U. 1994 nr 89 poz. 414 z późn. zm.)
- Rozporządzenie MSWiA z 7 czerwca 2010 r. w sprawie ochrony przeciwpożarowej budynków (Dz.U. 2010 nr 109 poz. 719, tekst jedn. Dz.U. 2023 poz. 822)
This is general information based on Article 62 of the Polish Construction Law (Prawo budowlane) and the Regulation of the Minister of the Interior of 7 June 2010 on fire protection. In disputes, the wording of the law and the position of the district building control inspector prevail.