- How often
- at least once a year
- Legal basis
- Art. 62(1)(1)(c) of the Construction Law
- Who does it
- a master chimney sweep or a person with building qualifications in the installations specialty
Updated: · DomPrzegląd editorial team
The periodic check of chimney ducts — smoke, flue and ventilation — is mandatory at least once a year. It applies to owners and managers of all buildings, including single-family houses: the exemption in Art. 62(2) covers only the check of elements exposed to weather, not chimneys and gas.
What the chimney sweep checks
- draught and clear passage of smoke, flue and ventilation ducts,
- tightness and technical condition of the ducts and their connections,
- condition of the chimney cap and parts above the roof,
- whether recommendations from the previous check were carried out.
After the check you receive a report. It is valid until the next check, i.e. for one year. Keep it: you will need it at the next inspection, during a building control visit and when reporting fire damage to your insurer.
Inspection is not cleaning
Besides the yearly check, fire regulations require regular cleaning of the ducts:
- from solid-fuel appliances (coal, wood, pellets) — at least every 3 months,
- from liquid and gas appliances — at least every 6 months,
- ventilation ducts — at least once a year.
Best time
Before the heating season, in September or October. Chimney sweeps are busiest in autumn, so book early.
What to prepare
- the report from the previous check
- access to cleanout doors in the basement and attic
- information on the fuel type and boiler output
Inspection in your voivodeship
- Lower Silesian
- Kuyavian-Pomeranian
- Lublin
- Lubusz
- Łódź
- Lesser Poland
- Masovian
- Opole
- Subcarpathian
- Podlaskie
- Pomeranian
- Silesian
- Holy Cross
- Warmian-Masurian
- Greater Poland
- West Pomeranian
Frequently asked questions
Is a chimney inspection mandatory in a single-family house?
Yes. The owner of a single-family house must have the chimney ducts checked at least once a year. The exemption in Art. 62(2) concerns a different part of the annual check.
What if the house has no stove, only ventilation?
Ventilation ducts are also covered. The scope is smaller, but the yearly check is still required.
Who pays for the inspection in a block of flats?
In a multi-family building the manager or housing community organises the check. As a flat owner you must give access to your flat on the agreed date.
Sources
- Ustawa Prawo budowlane (Dz.U. 1994 nr 89 poz. 414 z późn. zm.)
- Rozporządzenie MSWiA z 7 czerwca 2010 r. w sprawie ochrony przeciwpożarowej budynków (Dz.U. 2010 nr 109 poz. 719, tekst jedn. Dz.U. 2023 poz. 822)
This is general information based on Article 62 of the Polish Construction Law (Prawo budowlane) and the Regulation of the Minister of the Interior of 7 June 2010 on fire protection. In disputes, the wording of the law and the position of the district building control inspector prevail.